Stretcher van equipment: cots, mounts, and what states require on board
A stretcher van carries an elevating wheeled cot, with current Stryker and Ferno models rated for 700 pounds, fastened by a crash-tested mount built for that cot. Add chest, hip, knee and shoulder straps, a bracket for the rider's own oxygen, a stair chair or scoop for stairs, and clean linens with cleanup supplies. Virginia, Illinois, New York and Wisconsin put parts of that list into their rules.
On this page
The kit at a glance
Most of a stretcher van’s safety sits in four pieces: the cot, the mount that holds it, the straps that hold the rider, and the device that gets the rider down the stairs. The rest is oxygen brackets, linens, and cleanup supplies. The table maps each item to the state rules that name it.
| Item | What to look for | States whose rules name it |
|---|---|---|
| Wheeled cot | Elevating, 75 inches long and 22 wide at minimum, 3 inch non-porous mattress, rated above your heaviest rider | Virginia, Illinois, New York |
| Cot mount | Crash-stable, quick release, built or tested for that cot | Virginia, Illinois, New York |
| Rider straps | Chest, hip, and knee straps, with shoulder straps at the head end | Virginia, Illinois, New York, Wisconsin |
| Stair chair or scoop | Rated for your riders, stowed so it cannot fly loose | Virginia |
| Oxygen bracket | One crash-stable bracket per cylinder | Virginia, Illinois, New York |
| Linens | Pillows, sheets, and blankets, changed after each rider | Virginia, Illinois |
| Cleanup supplies | Gloves, red biohazard bags, disinfectant, hand sanitizer, emesis container | Virginia, Illinois |
The state comparison further down shows each state’s wording. For a state not listed here, look in its NEMT manual or your broker agreement.
Choosing the cot
Cots built for ambulances can meet stretcher van rules too; Virginia takes its cot standard from the federal ambulance specification, KKK-A-1822E. Three kinds are worth knowing.
Manual X-frame cots. These fold down to load and raise to working height. Stryker’s Performance-PRO XT is one example: 700 pound maximum capacity, 89 pounds empty, 80 inches long and 23 inches wide, with nine height positions. Stryker lists two operators for an occupied cot and a seven-year service life.
Chair cots. A chair cot folds into a seated shape, which helps in tight hallways and small elevators. Ferno’s PRO 28Z carries 700 pounds, weighs 96 pounds, and takes up 47 by 25 inches in the chair position.
Powered cots and loaders. A powered cot raises and lowers on a battery, and a powered loader lifts the cot into the van. Stryker’s Power-LOAD system lifts up to 700 pounds and runs on a 12 volt battery, but the system weighs 211.5 pounds in total, so check the van’s payload before you add one.
State rules set the minimum size. Virginia’s smallest allowed cot is 75 by 22 inches, or 79 inches long for cots with extra front roll-in wheels, topped by a mattress 3 inches thick or more under a non-porous cover rated to FMVSS 302. Illinois sets the same 75 by 22 inch floor for the primary wheeled litter.
Two numbers decide whether a cot fits your van and your riders:
- Rated capacity. Stryker’s stair chair specification states that its rated load covers the patient plus equipment and accessories. Treat a cot rating the same way and include the oxygen tank and the rider’s bags.
- Loading height. Stryker gives the Performance-PRO XT three load-height settings, for van decks under 30 inches, 30 to 34 inches, and 34 inches and above, and lists the Power-LOAD for decks of 22 to 36 inches. Ramp-loaded minivans and high-deck full-size vans call for different settings, so measure your deck before you order.
The mount holds the crash load
In a crash, the mount is what keeps the cot and rider in place, and three states set specific rules for it.
- Virginia calls for a crash-stable cot fastener that mounts at the side or center and lets go with a quick-release latch. Once installed, it must survive a 2,200 pound pull in the AMD Standard 004 litter retention test.
- Illinois wants a three-point fastener that is crash-stable and quick-release, naming the Ferno Type 175 or an equivalent. The IDPH inspection form also accepts an approved rail mount.
- New York requires a cot retention device attached as its maker instructs, compatible with the cot, and built by the company that made the cot.
Virginia and Illinois both permit just one stretcher rider per trip, so one mount per van satisfies both.
Makers test cot and mount pairs to SAE J3027, which Q’Straint calls the crash standard for ambulance-based equipment. The labels show why pairing matters:
| Product | What the maker states |
|---|---|
| Stryker Power-LOAD | Meets SAE J3027 with the Power-PRO XT cot and X-restraints |
| Stryker Performance-PRO XT | Recommended with Power-LOAD, floor mounts 6370 or 6377, or wall mount 6371 |
| Ferno iNLINE fastening system | SAE J3027 compliant with the iNLINE compatibility kit |
| Ferno Model 173 fastening system | Ratchet style, not SAE compliant |
| Q’Straint AMBULOK | Universal cot securement for NEMT vehicles with its OMNI floor; meets SAE J3027; a bracket adapts each cot |
A universal system lets you keep the cots you already own. For New York work, ask the broker first, because the state policy asks for a mount from the cot’s own maker. BraunAbility’s rear-entry NEMT minivan uses AMBULOK, and BraunAbility says the conversion is tested to SAE J3102 and J3027.
Straps that hold the rider
The cot keeps the rider on the van; straps keep the rider on the cot. Virginia goes into the most detail: chest, hip, and knee straps at a minimum, torso straps over the shoulders at the head end, quick-release buckles that close metal on metal, and webbing 2 inches wide or more in a material that is easy to disinfect. Illinois requires three strap sets and shoulder straps on the primary litter. New York requires the cot maker’s own restraint straps, used as the maker directs. Wisconsin requires a restraint for every rider on a cot or stretcher and requires the cot itself to be secured.
Keep a spare strap set in each van, so a frayed or soaked strap does not take the cot out of service for the day.
Stair chairs, scoops, and stairs
A rider on the second floor of a walk-up needs more than a cot. Virginia makes the provider supply a scoop, a Reeves, or a stair chair whenever a rider needs one. New York expects the stretcher service to get the rider over curbs, doorways, and steps in buildings without an elevator or ramp, bringing the people or extra equipment the move takes.
- Stair chair. Stryker’s Stair-PRO weighs 32.8 pounds, is rated for a 500 pound load, folds to 8 inches deep, and uses a track system to move a rider down stairs without lifting. Its restraint set has two cross-chest straps and an ankle strap. See stair chair for when crews use one.
- Scoop stretcher. Ferno’s Scoop EXL splits into two hinged halves that slide under the rider from each side, then lock together. It folds to 47 inches and comes with three restraints.
Whatever you carry must ride secured. Illinois requires every piece of equipment and every supply in a stretcher van to be secured so it is crash safe, and Wisconsin wants removable equipment stored securely so it cannot fly loose in a crash.
Oxygen: brackets, not supplies
In the states that address it, stretcher vans carry the rider’s oxygen, not their own. Virginia allows self-administered oxygen only when the tank is held to AMD Standard 003, the test for oxygen tank retention. Illinois wants a mounting bracket for every cylinder on board, crash-stable with a quick release. New York requires tanks to be secured and bars stretcher vehicles from carrying oxygen or oxygen supplies of their own; its stretcher staff may never help with the rider’s oxygen supply. Georgia’s manual says neither its NEMT vehicles nor their drivers, stretcher van crews included, can supply or administer oxygen, so riders bring portable, fully charged equipment.
Brackets come from the same suppliers as the rest of the kit. Stryker offers oxygen bottle holders at the head end, foot end, or backrest of its cots, and BraunAbility’s NEMT minivan offers single or double oxygen bottle mounts as options. The portable oxygen entry covers what riders usually bring.
Linens and infection control supplies
Every stretcher rider lies on your mattress, so linen and cleanup rules are specific. Illinois lists a pair each of pillows, sheets, and blankets, plus a box of disposable gloves, red bags labeled for biohazard isolation, and a CPR mask fitted with a safety valve. The state’s inspection form also checks for two pillowcases and an emesis container.
Virginia’s sanitation list for stretcher vehicles adds:
- Waterless antiseptic hand cleaner on board.
- Cleaning and disinfecting supplies on every vehicle, and every contaminated surface cleaned and disinfected after each rider, before the next one boards.
- Soiled items bagged or kept in covered containers, with red or orange bags for regulated waste.
- Clean linen or disposable sheets and pillowcases, changed after each rider.
- Blankets, pillows, and mattresses kept intact and clean.
Two federal points help you stock it. OSHA’s bloodborne pathogens standard lets red bags or red containers stand in for biohazard labels, and requires regulated waste containers that close and do not leak. EPA’s List S names disinfectants registered against bloodborne pathogens. The NEMT infection control guide covers cleaning steps between riders.
What each state’s rules name
These are the states whose rules name stretcher equipment. Elsewhere the list may sit in the broker contract instead, so check both the state manual and your agreement.
| State and rule | Cot | Mount | Straps | Oxygen | Other items named |
|---|---|---|---|---|---|
| Virginia, DMAS NEMT requirements (May 26, 2026) | Elevating wheeled cot, 75 by 22 inches minimum, 3 inch mattress | Side or center, quick release, 2,200 pound AMD 004 pull test | Chest, hip, knee, shoulder; 2 inch webbing | Self-administered only, AMD 003 bracket | Scoop, Reeves, or stair chair when a rider needs one; linens changed each use; red or orange bags |
| Illinois, 77 Ill. Adm. Code 515.840 and IDPH form | Wheeled litter, 75 by 22 inches minimum | Three-point quick release, Ferno 175 or equivalent; the IDPH form also accepts an approved rail mount | Three sets plus shoulder straps | Crash-stable bracket per cylinder | Pillows, sheets, blankets, CPR mask, red bags, gloves, emesis container, loading light |
| New York, Medicaid transportation policy (August 25, 2023) | Wheeled cot, used per the maker’s instructions | Made by the cot’s maker and compatible with it | The cot maker’s own straps | Tanks secured; no oxygen supplied by the vehicle | Protective equipment for drivers under OSHA 1910.1030 and 1910.134 |
| Wisconsin, DHS 105.39 | Cot or stretcher secured | Not specified | Restraint for each rider on a cot or stretcher | Not specified | Flashlight, first aid kit, fire extinguisher; restraints checked at least every 7 days |
| Georgia, DCH NEMT manual (July 1, 2026) | Vehicle accommodates a litter | Locking devices secure the litter in transit | Not specified | Vehicle not equipped to supply oxygen | Lights, sirens, and emergency equipment not required |
New Jersey is the opposite case. Its rules for mobility assistance vehicles bar stretchers and litters from those vehicles entirely.
Buying and checking the kit
A short buying order avoids the most expensive mistakes:
- Confirm your state and brokers use stretcher vans, and get their equipment list in writing.
- Size the cot to your heaviest regular rider plus oxygen and bags, and to your van’s deck height.
- Buy the mount the cot maker lists for that cot, or a universal system tested with it to SAE J3027. For New York work, confirm the mount meets the same-maker rule.
- Order a spare strap set, a second set of linens, and oxygen brackets for the cylinder sizes your riders bring.
- Add the stair chair or scoop your pickups call for, with a secured place to stow it.
- Keep the spec sheets, labels, and receipts together. Inspectors in Virginia and Illinois check the cot, mount, and supplies against their lists.
Train every crew member on the exact cot and mount in the van. In Virginia, both crew members need training approved by DMAS before they work a trip: first aid, handling bloodborne pathogens, and loading and unloading stretcher riders. For licensing and staffing, read the stretcher business guide; for who qualifies for the service, see stretcher vs gurney.
Keeping stretcher vans ready in HealthRide
In HealthRide, stretcher and stair-chair needs are matched on every assignment, so a stretcher leg only goes to a van with a stretcher space. Each driver checks the van in the app before the shift starts, which gives the crew a set moment to look over the cot, mount, and straps before the first pickup. The fleet management page shows how each vehicle’s capabilities are recorded.
Frequently asked questions
- What weight capacity should a stretcher van cot have?
- Aim above your heaviest regular rider plus whatever rides on the cot with them. Stryker's Performance-PRO XT manual cot and Ferno's PRO 28Z chair cot are both rated at 700 pounds. Stryker's stair chair specification counts the patient, equipment and accessories toward its rated load, and the same logic applies to a cot, so include the oxygen tank and bags.
- Can any cot be used with any cot mount?
- No. Mounts are built around specific cots. New York's Medicaid transportation policy wants the cot retention device to match the cot and come from the cot's own manufacturer. Ferno lists one of its mounts as SAE J3027 compliant only with a compatibility kit, and another as not SAE compliant. Universal systems such as Q'Straint's AMBULOK use a bracket fitted to each cot.
- What is AMD Standard 004?
- It is the litter retention system test from the Ambulance Manufacturers Division of the National Truck Equipment Association. Virginia's Medicaid NEMT requirements say an installed stretcher fastener has to hold 2,200 pounds of pull in the AMD Standard 004 test. A companion standard, AMD 003, tests oxygen tank retention, which Virginia also requires for riders who bring oxygen.
- Is the rider's oxygen allowed in a stretcher van?
- In most states, only the rider's own, self-administered oxygen, held in a bracket. Virginia wants tanks secured to the AMD Standard 003 test, and Illinois wants a crash-stable, quick-release bracket for every cylinder. New York bars stretcher vehicles from carrying oxygen supplies of their own, and Georgia's manual says neither its NEMT vehicles nor their drivers, stretcher van crews included, can supply or administer oxygen.
- Do stretcher vans have to carry a stair chair?
- Plan on one. Virginia puts it on the provider to bring the scoop, Reeves, or stair chair a rider needs. New York expects stretcher services to get riders past curbs, doorways, and steps wherever a building lacks an elevator or ramp, using extra staff or equipment. Stryker's Stair-PRO weighs 32.8 pounds and is rated for 500 pounds.
- Can a minivan be set up as a stretcher van?
- Some converters build one. BraunAbility's rear-entry NEMT minivan lowers the floor, loads a cot on a 1,000 pound ramp, and locks it with a Q'Straint cot securement system. State rules still decide. Illinois requires room for two attendants and rules out sedans, and SUVs with under three passenger doors on a wheelbase shorter than 100 inches. New Jersey bars stretchers from mobility assistance vehicles entirely.